We supply and install the Platino Retrofit Emission Control Device (RECD) — a Type Approved, ARAI & ICAT certified solution that brings your existing DG set into compliance with State Pollution Control Board and CPCB emission norms, without replacing the genset.
The National Clean Air Programme (NCAP) has identified that 7–18% of city pollution comes from stationary diesel generators, and WHO estimates ambient air pollution causes over 4 million deaths a year worldwide. Government has responded with clear rules.
Under directions from the National Green Tribunal (O.A. No. 681/2018) and the MoEFCC National Clean Air Plan, every operational DG set must either fit a Retrofit Emission Control Device or shift to a gas-based generator.
Covers DG sets from 19 kW to 10 MW, compatible with all major engine makes — Cummins, CAT, Kirloskar, KOEL, Volvo Penta, Perkins, MTU, Mahindra Powerol and more.
Over 95% reduction in Particulate Matter, plus catalytic oxidation of Hydrocarbons (HC) and Carbon Monoxide (CO) — comfortably clearing the CPCB 70% minimum.
ARAI & ICAT type-approved across the 25 kVA–1000 kVA range, with triple ISO certification (9001, 14001, 45001) and a patented design registered in India and the UK.
Engine back-pressure stays within permissible limits, so there's no adverse impact on engine performance or fuel efficiency.
No rotating parts, no consumables, and no external power needed — self-cleaning through continuous passive regeneration during genset operation.
Oval, triangular, cylindrical or rectangular housings with a nano thermal ceramic-blanket coating, fitted in as little as 1–5 days without major modification.
Backed by an assured warranty, PAN-India service network, and remote/IoT monitoring options for larger installations.
We check the DG set's kVA rating, engine make and stack layout to recommend the right RECD size.
A Platino RECD is matched to your genset from our type-approved 19 kW–10 MW range.
Fitted onto the exhaust line without major modification — typically completed in 1–5 days.
Flue-gas tested, handed over with type-approval documentation for pollution board records.
Minimum reduction required: 70% of PM, CO and HC. Requirements below apply to operational DG sets above the threshold kVA in each state.
| State | Upto 800 kW | Above 800 kW | Threshold |
|---|---|---|---|
| Karnataka | Yes | Yes | Above 125 kVA |
| Tamil Nadu | Yes | Yes | Above 62 kW |
| Kerala | Yes | Yes | Above 125 kVA |
| Delhi & NCR | Yes | Yes | Above 125 kVA |
| Maharashtra, Gujarat, Jharkhand, Telangana, Odisha | Yes | Yes | Above 125 kVA |